SM 01 Sensor module

The current trend is to map furnace controls completely with PLCs without special control devices.
We are taking this into account with the sensor module presented here and enabling nitriding ratio control and online calculation of carbon diffusion at control level.

The device is suitable for integration in PLC control systems for new systems or modernizations, but also for retrofitting in existing control systems with conventional controllers.

Divider

Description of funtion

Functions

The sensor module enables nitriding ratio control and online calculation of carbon diffusion at control level as well as carbon diffusion calculation with target size control and graphical display of the carbon diffusion profile via web server.

Connections

  • Supply 24V DC, max. 100 mA
  • Inputs / outputs:
    • 1 x EMF oxygen probe signal 0 - 1600 mV, input impedance typically 800 MΩ, resolution 24 bit
    • 1 x thermocouple input, type configurable, resolution 19 bit
    • 1 x analog input 0/4 - 20 mA, resolution 24 bit
    • (the three analog inputs are isolated from the supply voltage and from each other)
    • 2 x analog output 0/4 - 20 mA, resolution 16 bit
    • 2 x digital output 24 V, 250 mA, short-circuit proof
    • 1 x Ethernet, Modbus/TCP slave, and MQTT protocol, web server for configuration

Models

Versions

Available in different versions:

  • as a module for connecting an oxygen probe
  • as a module for connecting an oxygen probe for carburizing processes with C-level calculation
  • as a module for connecting an oxygen probe for carburizing processes with C-level calculation

Newsletter

Always have the latest information from Demig

Always stay up to date on our process control systems and process controllers.