841. Oxygen probe SSK 02 - Measurement  
Measurement The SSK02 oxygen probe is used to determine the carbon level (C level) in industrial furnaces for processes such as gas carburizing, case hardening, hardening etc.. The measurement is…  
842. Oxygen probe SSK 02 - The oxygen probe SSK 02  
The oxygen probe SSK 02 With closed zirconium dioxide tube (ZrO2) Suitable for the processes: Gas carburizing, case hardening, carbonitriding, neutral hardening and tempering Non-catalytic…  
843. H2S Hydrogen sensor - Function  
Function The sensor is characterized by robustness, reliability and durability. It is therefore particularly suitable for measuring furnace atmospheres at high temperatures and high hydrogen…  
844. H2S Hydrogen sensor - Measurement  
Measurement The H2S hydrogen sensor is used to determine the hydrogen level in industrial furnaces for nitriding and nitrocarburizing processes. The measurement is based on the thermal…  
845. H2S Hydrogen sensor - The hydrogen sensor H2S  
The hydrogen sensor H2S Measuring principle: Thermal conductivity Measuring block temperature: 100 °C to avoid ammonium carbonate precipitation and condensate formation Measuring range: 0…  
846. SM 01 Sensor module - Versions  
Versions Available in different versions: as a module for connecting an oxygen probe as a module for connecting an oxygen probe for carburizing processes with C-level calculation as a module…  
847. SM 01 Sensor module - Connections  
Connections Supply 24V DC, max. 100 mA Inputs / outputs: 1 x EMF oxygen probe signal 0 - 1600 mV, input impedance typically 800 MΩ, resolution 24 bit 1 x thermocouple input, type…  
848. SM 01 Sensor module - Functions  
Functions The sensor module enables nitriding ratio control and online calculation of carbon diffusion at control level as well as carbon diffusion calculation with target size control and graphical…  
849. SM 01 Sensor module - SM 01 Sensor module  
SM 01 Sensor module The current trend is to map furnace controls completely with PLCs without special control devices. We are taking this into account with the sensor module presented here and…  
850. RLV 01 Reference air supply for oxygen probes - Functions  
Functions Control of the reference air volume and the purge air volume for an oxygen probe by means of infinitely variable modulation of the pumps Generation, storage and display of fault…  